Permit: T05PL00963

Parcel: 121092820

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05PL00963

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/29/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) ALL CORRECTIONS HAVE BEEN MADE OK
2) OK FOR C OF O
3) UCC LEFT AT METER
07/22/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
18 P.S.I TEST IS OK - WATER HEATER VENT NOT CONNECTED PROPERLY INSIDE CLOSET.
PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS
DO NOT USE TAPE - SECURE THE DOUBLE WALL VENT PIPE ON THE ROOF & PROVIDE AN APPROVED ROOF JACK ON VENT PIPE - PROVIDE A MIN. 1" CLEARANCE FROM COMBUSTIBLE WHERE VENT PENETRATES THE ROOF -- SECURE DRAFT DIVERTER ON WATER HEATER.
07/07/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) ONCE AGAIN NO ONE HOME. PLEASE RESCHEDULE AN INSPECTION WHEN AN ADULT MAY BE PRESENT. 2) SHALL PAY A REISNPECTION FEE PRIOR TO THE NEXT INSPECTION.
06/30/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*NO ONE HOME!
06/22/2005 PLUMBING - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
1) PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME
06/08/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHALL PROVIDE DBL WALL FLU VENT ABOVE ROOF AND PROVIDE AN APPROVED B-1 CAP
2) FLU VENT THRU ROOF SHALL TERMINATE A MINIMUM OF 3'-0" ABOVE COOLER
3) SHALL PLUG WATER HTR DRAIN PAN