Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T05PL00908
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 05/20/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE APPROVED DBL WALL VENTS ON WATER HEATER AND FURNACE WITH APPROVED CAPS 2) PROVIDE PRESSURE GAUGE THAT WORKS PROPERLY 3) PROVIDE A NEW T & P RELIEF VALVE 4) PROVIDE HIGH AND LOW COMBUSTION AIR VENTS IN WATER HEATER ENCLOSURE 5) PROVIDE A BOND WITH THE ELECTRIC SERVICE 6) BE SURE TO MAINTAIN MINIMUM 1" CLEARANCE FROM COMBUSTIBLES AROUND DBL WALL VENTS |