Permit: T05PL00893

Parcel: 118220170


Addresses:

237 W 23RD ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/23/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) ALL CORRECTIONS HAVE BEEN MADE
05/19/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/18/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL CUT OFF THE THREADS @ THE END OF T & P DRAIN. 2) SHALL PROVIDE 3/4" UP TO THE FIRST 1/2" SUPPLY. 3) SHALL PROVIDE A FEMALE COUPLING AND PLUG. FOR C .O EXTENSION. 4) SHALL LOCATE GAS SHUT OFF VALVE A MIN. OF 3 FT FROM REGULATOR FOR WATER HTR. 5) SHALL SEAL ALL WATER SUPPLY PENTRATIONS THRU WALL. 6) SHALL PROVIDE INSULATION ON ALL EXTERIOR WATER SUPPLIES.