Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/19/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* ACCESS GRANTED CORRECTIOS MADE |
| 05/18/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 10 PSI AIR TEST FROM METER NEW SCOTCH COAT UNDERGROUND UP AT BUILDING OVERHEAD TO EXISTING SERVICE ENTRY TO WATER HEATER, FURNACE & (BARBEQUE EXISTING LINE) OK. 1) WATER HEATER TEMPERATURE & PRESSURE RELIEF TO BE RIDGID PIPING GRAVITY DRAIN TO DAYLIGHT. 2) VENT FROM WATER HEATER TO BE MADE UP CORRECTLY, DRAFT SPACE EXPOSED T SCREWED TOGETHER. 3) HARD PIPE GAS PIPING THRU FURNACE APPLIANCE HOUSING. S.W GAS 889-1888. 4) PROVIDE BONDING OF BLD GAS |