Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/26/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) 10 PSI TEST IS OK 2) CORRECTIONS HAVE BEEN MADE 3) LEFT GAS CARD |
|
| 05/13/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) VENT CONNECTOR ON FURNACE IS INSTALLED UPSIDE DOWN 2) CRIMPED ENDS MUST GO SAME DIRECTION AS AIR FLOW 3) PROVIDE MINIMUM 3 SCREWS IN EACH JOINT OF FURNACE AND WATER HEATER VENT CONNECTORS 4) GAS LINE NOT HOLDING PRESSURE, PROVIDE 10 LB TEST 5) NEW PLASTIC GAS LINE INSTALLED TO FUTURE BBQ PIT AND COVERED WITHOUT ANY INSPECTIONS, NO TRACER WIRE INSTALLED 6) NEED TO SEE TRANSITION FROM PLASTIC TO STEEL PIPE 7) PROVIDE THE TOTAL BTU DEMAND FOR THE FUTURE BBQ 8) PLASTIC PIPE NEEDS TO BE RAN TO THE POINT OF CONNECTION AND TESTED ALONG WITH THE HOUSE PIPING 9) ALL PIPE PASSING THRU CONCRETE ON MASONRY MUST BE ISOLATED FROM THE CONCRETE |