Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/10/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :*1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WATER HEATER FLU VENT, OK. FURNACE FLU VENT OK. 4) NOTE: OWNER WILL REPLACE T & P VALVE | |
| 05/06/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A MINIMUM 10 POUND PRESSURE TEST ON GAS PIPING 2) NEED TO HAVE ACCESS TO ALL GAS APPLIANCES 3) WATER HEATER VENT MUST HAVE A MINIMUM 1" CLEARANCE AT ROOF PENETRATIONS 4) EXTEND T & P RELIEF DRAIN TO WITHIN 24" OF THE FLOOR AND DO NOT HAVE THREADS ON BOTTOM OF PIPE |