Permit: T05PL00803

Parcel: 130101670


Addresses:

3150 E 26TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/09/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
05/04/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) WHEN METER IS PINNED BY SOUTHWEST GAS ENTIRE GAS SYSTEM SHALL BE BROUGHT UP TO CURRENT CODE REQUIREMENT AND BE TESTED MINIMUM 10 PSI FOR 15 MINUTES
2) TEMPERATURE AND PRESSURE RELIEF DEVICE SHALL BE RATED TO MINIMUM BTU REQUIREMENT OF DEVICE
3) GAS FLEX TO MINIMUM BTU REQUIREMENT OF DEVICE
4) GAS REGULATOR TO BE VENTED TO OUTSIDE OF BLDG
5) PROVIDE PROOF OF 1" CLEARANCE FROM COMBUSTIBLES OF VENT FROM WATER HEATER
6) PROVIDE PROPER BONDING OF BLDG GAS PIPING