Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* CORRECTION MADE. GAS CARD AT METER S.W GAS 889-1888 | |
| 05/16/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NO READY. 1) MAKE WEATHER PROOF ROOF FLASHINGS. 2. SEE NOTE# 11 FROM 5/11/05 & NOTE #10. 3) PROVIDE WEATHER COLLAR ON WATER HEATER & FURNACE VENT THRU ROOF. 4) REMOVE TAPE AT DRAFT SPACE AT SINGLE TO DOUBLE WALL VENT CONNECTION | |
| 05/09/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*USE APPROVED PRIMER ON ALL TAPED JOINTS. PROVIDEE A MIN 10 LB TEST ON ALL GAS PIPING RECONNECT T & P RELIEF DRAINS. PROVIDE MIN 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS. |