Permit: T05PL00710

Parcel: 122121270

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T05PL00710

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
04/15/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :* 14 PSI TEST IS OK. LEFT GAS CARD.
04/14/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) PROVIDE ROOF FLASHINGS AT ALL PIPE PENETRATIONS THRU ROOF. 2) SECURE GAS DROP AT WATER HEATER. 3) WATER HEATER VENT REQUIRE 1" MINIMUM CLEARANCE FROM COMBUSTIBLES. 4) SEAL WATER HEATER T & P DRAIN PIPE PENTRATION THRU BUILDING, AND TERMINATE 6" -24" FROM FINISH GRADE.