Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/09/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* 1) CALLE AARON AT 8:04AM HE SAID HE NEEDED TIME TO GO TO SITE AND PRESSURIZE LINE. |
| 04/08/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :10 PSI TEST SHALL BE ON SYSTEM AT TIME OF INSPECTION. 1) ALL UNDERGROUND PIPING TO BE SCOTCH COATED PIPE. 2) ALL FITTINS & TOOL MARKS TO BE ( PRIMED USING PIPE PRIMER) AND THEN TAPED. 3) WHERE UNIONS ARE NECESSARY LOFT-RIGHT NIPPLES & COUPLINGS SHALL BE USED. 4) ALL APPLIANCES TO HAVE AGA OR CSA APPROVED GAS VALVES. 5) PROVIDE BONDING OF BUILDING-GAS PIPING. 6) UNDERGROUND PIPING TO BE ON FIRM BEDDING FOR SUPPORT ( NO BRIDGING). 7) WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN TO BE FULLL SIZE APPROVED MATERIAL, GRAVITY DRAIN TO DAYLIGHT. |