Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05PL00675

Parcel: 131040610


Addresses:

4915 E 24TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/09/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 1) CALLE AARON AT 8:04AM HE SAID HE NEEDED TIME TO GO TO SITE AND PRESSURIZE LINE.
04/08/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :10 PSI TEST SHALL BE ON SYSTEM AT TIME OF INSPECTION. 1) ALL UNDERGROUND PIPING TO BE SCOTCH COATED PIPE. 2) ALL FITTINS & TOOL MARKS TO BE ( PRIMED USING PIPE PRIMER) AND THEN TAPED. 3) WHERE UNIONS ARE NECESSARY LOFT-RIGHT NIPPLES & COUPLINGS SHALL BE USED. 4) ALL APPLIANCES TO HAVE AGA OR CSA APPROVED GAS VALVES. 5) PROVIDE BONDING OF BUILDING-GAS PIPING. 6) UNDERGROUND PIPING TO BE ON FIRM BEDDING FOR SUPPORT ( NO BRIDGING). 7) WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN TO BE FULLL SIZE APPROVED MATERIAL, GRAVITY DRAIN TO DAYLIGHT.