Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T05PL00649
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :*1) GAS PRESSURE TEST IS OK. 2) ALL CORRECTIONS HAVE BEEN MADE 3) WALL HTR HAS BEEN INSTALLED AS PER INSTALLATION STANDARDS | |
04/06/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL LOCATE GAS LINE IN HOUSE TO WALL HTR MIN. 6" ABOVE FLOOR. 2) SHALL PROVIDE FLU VENT & CAP FOR WATER HTR AND TERMINATE MIN. 2" ABOVE ROOF WITH PROPER CLEARANCES. 3) SHALL HARD? PIPE INTO WATER HTR ENCLOSURE THEN LOCATE VAVLE & FLEX CONNECTOR. 4) SHALL PROVIDE 2- 10X10 LOUVER GRILLS LOCATED 12" ABOVE FLOOR AND 12" BELOW CEILING @ WATER HTR ENCLOSURE. 5) SHALL HAVE AIR TEST @ TIME OF INSPECTION. |