Permit: T05PL00642

Parcel: 138141730


Addresses:

101 W CALLE GARCIA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/15/2005 PLUMBING - FINAL Approved
04/11/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL PROVIDE BLOCKS AND STRAPS FOR GAS LINE ON ROOF EVERY 6'-0" MIN 1 1/2" ABOVE ROOF. 2) SHALL REMOVE UNION IN LINE OR LOCATE AN APPROVED GAS SHUT OFF VALVE BEFORE THE UNION. 3) SHALL PROVIDE ROOF FLASHING ON ROOF AND SEAL GAS LINE PENETRATION. DO NOT CUT THE FLASHING TO INSTALL. 40 SHALL REMOVE FLEX LINE IN T & P DRAIN AND HARD PIPE T & P DRAIN 5) RE TEST THE SYSTEM.
04/08/2005 PLUMBING - FINAL Cancelled
04/08/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* NOT READY FOR INSPECTION