Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2005 | PLUMBING - FINAL | Approved | ||
| 04/11/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE BLOCKS AND STRAPS FOR GAS LINE ON ROOF EVERY 6'-0" MIN 1 1/2" ABOVE ROOF. 2) SHALL REMOVE UNION IN LINE OR LOCATE AN APPROVED GAS SHUT OFF VALVE BEFORE THE UNION. 3) SHALL PROVIDE ROOF FLASHING ON ROOF AND SEAL GAS LINE PENETRATION. DO NOT CUT THE FLASHING TO INSTALL. 40 SHALL REMOVE FLEX LINE IN T & P DRAIN AND HARD PIPE T & P DRAIN 5) RE TEST THE SYSTEM. |
|
| 04/08/2005 | PLUMBING - FINAL | Cancelled | ||
| 04/08/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NOT READY FOR INSPECTION |