Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
Permit Number - T05PL00636
Inspection Description - PLUMBING - GAS PRESS TEST FNL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/17/2005 | PLUMBING - GAS PRESS TEST FNL | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) ALL CORRECTIONS HAVE BEEN MADE. | |
04/11/2005 | PLUMBING - GAS PRESS TEST FNL | Not ready for Inspection | IVRS - Inspection :* 1) SHALL PROVIDE A FLU VENT CAP FOR WATER HTR FLU VENT 2) CANNOT LOCATE A BUSHING IN GAS LINE IN A CONCEALED LOCATION. 3) SHALL PROVIDE (30 SHEET METAL SCREWS PER JOINT@ WATER HTR FLU VENT AND @ APPLIANCE COLLAR. 4) SHALL PROVIDE AGA OF CSA GAS SHUT OFF VALVES FOR ALL APPLIANCES WITH THERE FLEXES. 5) RE TEST THE SYSTEM. |