Permit: T05PL00623

Parcel: 135083070


Addresses:

7507 E 29TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/08/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
03050 - 13PSI TEST FROM MOTOR UNDERGROUND TO EXISTING SERVICE ENTRANCE TO WATER HEATER & FURNACE OK
03090 - NOT READY - 1. PROVIDE BONDING OF BUILDING GAS PIPING #4 WIRE.
2. PROVIDE PRIMOR & TON MIL TAPE AT RESOR.
3. PROVIDE 3 GALV SCREWS AT EACH JOINT OF FLUE VENT PIPING.
4. PROVIDE DRAIN AT WATER HEATER.
12/07/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*11:15 SEE NOTE ABOVE FROM 4/7/05 INSPECTION.
04/08/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :* 1) PROVIDE 10 PSI MINIMUM TEST ON GAS SYSTEM WITH NO PRESSURE DROP FOR 15 MINUTES. 2) NEW UNDERGROUND PIPING TO BE SCOTCH COATED.
04/07/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :* PLEASE HAVE AN ADULT PRESENT TO PROVIDE ACCESS TO GAS PIPING SYTEM AT TIME OF REINSPECTION 11:45