Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SHALLE EXTEND T & P DRAIN TO DAYLIGHT AND TERMINATE MIN. 6" ABOVE GROUND 24" MAX WITH A 90 DEGREE. 2) SHALL PROVIDE A P & TRAP FOR WASHER WASTE LINE. 4) CALL FOR FINAL INSPECTION | |
| 04/03/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL REMOVE UNION IN LINE BY METER 2) SHALL REPLACE OLD NAD RUSTED FLU VENT FOR WATER HTR & FURNACE AND PROVIDE (3) SHEET METAL SCREEENS PER JOINT AND @ APPLIANCE COLLAR. 3) SHALL REPLACE OLD SHUT OFF VALVE FOR FURNACE AND REPLACE WITH AGA OR CSA VALVE. 4) SHALL REPLACE T & P VALVE THAT IS NOT WORKING. 5) PRESSURE TEST WAS BELOW 10 LBS MIN. CHECK THE SYSTEM. |