Permit: T05PL00598

Parcel: 132110220

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/08/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) SHALLE EXTEND T & P DRAIN TO DAYLIGHT AND TERMINATE MIN. 6" ABOVE GROUND 24" MAX WITH A 90 DEGREE. 2) SHALL PROVIDE A P & TRAP FOR WASHER WASTE LINE. 4) CALL FOR FINAL INSPECTION
04/03/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL REMOVE UNION IN LINE BY METER 2) SHALL REPLACE OLD NAD RUSTED FLU VENT FOR WATER HTR & FURNACE AND PROVIDE (3) SHEET METAL SCREEENS PER JOINT AND @ APPLIANCE COLLAR. 3) SHALL REPLACE OLD SHUT OFF VALVE FOR FURNACE AND REPLACE WITH AGA OR CSA VALVE. 4) SHALL REPLACE T & P VALVE THAT IS NOT WORKING. 5) PRESSURE TEST WAS BELOW 10 LBS MIN. CHECK THE SYSTEM.