Permit: T05PL00594

Parcel: 136240630


Addresses:

6721 E 39TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/03/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) GAS FIRED WATER HEATER INSTALLED OK
03/30/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) WATER HEATER TEMPERATURE & PRESSURE RELIEVE TO GRAVITY DRAIN TO DAY LIGHT & TERMINATE AT 90 DEGREE DOWN. 90 DEGREE FITTING LEAKS IN WATER HEATER CLOSET. 2) WATER HEATER VENT WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOP OF COOLER INTAKE.