Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05PL00589
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/13/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
04/03/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE WATER HTR FLU VENT FOR WATER HTR AND TERMINATE MIN 2" ABOVE ROOF WITH CAP AND PROVIDE ( 3) SHEET METAL SCREENS PER JOINT AND @ APPLIANCE COLLAR. 2) SHALL PROVIDE CPVC, GALVANIZED OR COPPER MATERIAL FOR T& P DRAIN 30 SHALL PROVIDE GAS SHUT OFF VALVE AND FLEX CONNECTOR. |