03/29/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 15 PSI AIR TEST FROM METER TO POOL HEATER, WATER HEATER, AND FURNACE OK CORRECTION MADE GAS CARD AT METER. S.W GAS 889-1888
03/28/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED ROOF FLASHING FOR PIPE PENETRATIONS
2) VENT FROM FURNACE WHEN WITHIN 10' OF COOLER INTAKE TO BE 2' ABOVE TOP OF COOLER INTAKE
3) PROVIDE 3-GALV SCREWS AND PROVIDE TAPE FROM SINGLE TO DBL WALL AT FURNACE
4) INSTALL BONDING FOR GAS PIPING
5) FINISH PIPING TO POOL HEATER. RETEST