Permit: T05PL00558

Parcel: 114469100

Inspection Status: Approved

Inspection History: SITE - SEWER

Date Description Inspector Results Comments
01/27/2006 SITE - SEWER Approved IVRS - Inspection :*
03055, 03035, 03040 THIS WORK NOT FOR THIS PERMIT - WILL BE SEEN AT EACH BUILDING BUILD OUT
03057 - P.D.E.Q DISCHARGE AUTHORIZATION TURNED IN
06/08/2005 SITE - SEWER Partial Approval IVRS - Inspection :* MANHOLE # 19 VACUUM TEST OK. 20 SEC 2/10 DROP.
MANHOLE # 20 VACUUM TEST OK. 20 SEC NO DROP.
MANHOLE # 16 VACUUM TEST OK. 18SEC NO DROP.
MANHOLE # 15 VACUUM TEST OK. 15 SEC NO DROP.
MANHOLE # 17 VACUUM TEST OK.18 SEC 3/10 DROP.
MANHOLE # 6 VACUUM TEST OK. 11 SEC NO DROP.
MANHOLE # 9 VACUUM TEST OK. 13 SEC NO DROP.
MANHOLE # 10 VACUUM TEST OK. 11 SEC NO DROP.
05/31/2005 SITE - SEWER Partial Approval IVRS - Inspection :* MANHOLE #13 VACUUM TEST OK. MANHOLE # 16 NOT READY. MANHOLE #15 NOT READY. MANHOLE #17 NOT READY
05/12/2005 SITE - SEWER Partial Approval IVRS - Inspection :* VACUUM TEST ON MAN HOLE 11, 12,18 VACUUM TEST OK. VACUUM TEST 10,15 NOT READY PLEASE MAKE REPAIRS & CALL AGAIN.
05/11/2005 SITE - SEWER Partial Approval IVRS - Inspection :* VACUUM TEST ON MAN HOLES #4,#3, #2,#1, #7, #8. TEST OK
05/10/2005 SITE - SEWER Not ready for Inspection IVRS - Inspection :* NOBODY AROUND TO VACUUM TEST MH
05/09/2005 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
05/03/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
05/02/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
04/28/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
04/27/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
1) TEST OK FROM M-H #1 TO EXISTING TEST ON 8"
2) TEST OK FROM M-H #2 TO M-H #1 TEST OK
3) TEST OK FROM M-H #2 TO M-H #3 8"
4) TEST OK FROM M-H #3 TO M-H #4 8"
5) TEST OK FROM M-H #3 TO 160' 6" LOT #58
04/25/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 6" HCS HAS BEEN INSTALLED FOR LOT #39 AS PER PLAN FROM EXISTING M-H 6597-14. TO M-H #19 TO M-H #20 AND ALS HCS
2) NOTE: INSTALL DIP AT LOTS 32-33 OR PROVIDE A REVISED PLAN
04/21/2005 SITE - SEWER Partial Approval IVRS - Inspection :* HCS HAVE BEEN INSTALLED BETWEEN M-H # 6597-13 & M-H #16
04/20/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
04/19/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
04/18/2005 SITE - SEWER Partial Approval IVRS - Inspection :* DIP FROM M-H #6 PLEASE PROVIDE INFO ON TRANSMISSION BANDS FROM DIP SDR 35 SEE REQUEST 4/5/05. FROM M-H 17-HCS DIP-OK
04/15/2005 SITE - SEWER Partial Approval IVRS - Inspection :* FROM M-H #8 TO M-H #7 FROM M-H # 7 TO M-H #6 DIP FROM M-H #6 NOT READY. FROM M-H #8 TO M-H # 17 OK. ALSO HCS OK BETWEEN M-H # 7 & #6 OK
04/14/2005 SITE - SEWER Partial Approval IVRS - Inspection :* PLEASE NOTE WILL REQUIRE VERIFICATION OF GRADE ON SEWER & ITS BRANCHES ALSO VACUUM TEST ON ALL MANHOLES. LOW PRESSURE AIR TEST ALL CO UP TO GRADE. CERTIFICATE OF COMPLETRION FROM DEQ AT TIME OF FINA. ALSO WILL NEED DETAIL OF PROPER INSTILLATION FO TRANSISSION BETWEEN DEP AND SDR 35. 4" HCS FROM M-H # 10 OK. ALSO HCS BETWEEN M-H #9 & M-H #8 OK SUBJECT TO ABOVE.
04/13/2005 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
04/12/2005 SITE - SEWER Partial Approval IVRS - Inspection :* HCS FOR TRUNK LINE BETWEEN M-H #12 & M-H # 11. ALSO HCS INSTALLED IN TRUNK LINE FROM M-H#11 TO M-H #10
04/11/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
04/08/2005 SITE - SEWER Partial Approval IVRS - Inspection :* FROM M-H # 11-TO M-H # 10 TRUNK ONLY WILL NEED TO COMPLETE HCS-CONTRACTOR WILL PROVIDE VERIFICATION OF GRADE LOW PRESSURE AIR TEST & VACUUM TEST AT LATER-ALSO SE OTHER NOTES
04/07/2005 SITE - SEWER Partial Approval IVRS - Inspection :* FROM 14-TO M-H #13 TO M-H #12 TO M-H#12. TRUNK LINE ONLY-WILL INSTALL HCS AT LATER DATE.
04/06/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
1) PLEASE PROVIDE THE STANDARD ENGINEERING DETAIL ON THE PROPER INSTALLATION OF STANDARD DUCTILE HCS CONNECTION FROM SDR-35-DUCTILE IRON PIPE MATERIALS. ALSO PROVIDE SPEC ON DIP ? CLASS NOT ON PLAN ? SEAL. PLEASE PROVIDE LISTING ON ? BAN USED FROM SDR-35-DIP
3) ALL HCS CONNECTIONS HAVE BEEN INSTALLED ON SEWER LINE A-WILL NEED ABOVE INFO BEFORE APPROVAL IS GIVEN
CONTRACTOR WILL PROVIDE AIR TEST VACUUM TEST AND VERIFICATION OF GRADE AT LATER DATE
04/05/2005 SITE - SEWER Partial Approval IVRS - Inspection :* TRUNK LIVE ONLY FROM M-H #2 TO M-H # 3 7 FROM M-H #3 TO MH #4 6" LINE FROM M-H #3 TO END OF RUN WITH TWO WAY C.O CONTRACTOR WILL TEST AT LATE DATE. PLEASE NOTE WILL NEED TO KNOW WHAT TIYPE OF TRANSMISSION TO BE USED FROM SDR 35-DIP-ALSO CLASS OF DIP NOT ON SPEC.
04/01/2005 SITE - SEWER Not ready for Inspection IVRS - Inspection :* 8" FROM EXISTING M-H TO M-H #1 OK FROM M-H #1 TO M-H #2 8" OK. OK TO BACKFILL CONTRACTOR WILL PROVIDE VARIFICATION OF GRADE & LOW PRESSURE TEST AT LATER DATE. ALSO WILL REQUIRE VACUUM TEST ON MANHOLES. NEED TO COMPLETE HCS FOR LOTS 9 & 10
03/30/2005 SITE - SEWER Not ready for Inspection IVRS - Inspection :* INFO ONLY