Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/19/2005 PLUMBING - FINAL Approved IVRS - Inspection :* CORRECTION MADE GAS CARD AT METER SW GAS 889-1888
04/18/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* NO CAULK FLASHINGG IS A COMBUSTIBLE MATERIAL. PROVIDE APPROVED VENT FLASHING ASSEMBLY FOR DOUBLE WALL VENT PIPING
04/14/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* RECEIPT FOR WATER HEATER ADDTION TO PERMIT ON SITE. SEE NOTE #5 FROM 4/6/05 INSPECTION. USE CORRECT FLASHING AND NO PLASTIC ROOF CEMENT ON VENT PIPING, IT IS COMBUSTIBLE.
04/06/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) GAS VALVE AT SERVICE ENTRY LOCATION TO BE BEFOE UNION. 2) HAVE WATER HEATER ADDED TO YOUR PERMIT. 3) HAVE APPROVED GAS VALVE CSA OR AGA ON SITE FOR STOVE. 4) WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING TO BE RIDGID FULL SIZE PIPING GRAVITY DRAIN TO DAY LIGHT. 5) VENT FROM WATER HEATER TO BE DOUBLE WALL THRU ROOF WITH APPROVED VENT CAP AT TERMINATION AND ROOF FLASHING. 6) PROVIDE BONDING OF BUILDING GAS PIPING