Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/21/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 1) UPPER CONNECTION OK OK TO COVER.
03/18/2005 PLUMBING - FINAL Partial Approval IVRS - Inspection :* FROM POINT OF CONNECTION FROM NEW 4" BUILDING SEWER AND 3" EXISTING BUILDING SEWER THRU CLEANOUTS TO CONNECTION TO EXISITING 4" CLAY FROM EXISINTING MAIN SEWER WATER TEST OK. 1) NEED TO VIEW 3" CONNECTION TO 4" ABS AT UPSTREAM END ONLY.
03/16/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) TEST HAS BEEN DROPPED, FINAL CONNECTIONS HAVE NOT BEEN MADE. MAKE FINAL CONNECTIONS AND RECALL FOR INSPECTION. NEED TO SEE CONNECTIONS-BOTH ENDS. 2) PLEASE REMOVE CONCRETE FROM ATOP THE PIPE AND SHADE PIPE WITH AT LEAST 6" CLEAN FILL BEFORE INTRODUCING LARGE AGGREGATE.
03/15/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) INSTALL ALL PIPE-MAKE ALL CONNECTIONS AND RECALL FOR INSPECTION. THE POSTED ADDRESS IS SUPPOSED TO MATCH THE ADDRESS ON THE PERMIT