Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 25 PSI AIR TEST ON EXSISTING PIPING EXCEPT NEW RISER AT GAS METER TO WATER HEATER ( 1) AND STOVE ONLY. ALL WALL HEATERS ARE CAPPED AND REMOVED. ADVISED OWNER TO SUPPORT GAS PIPING EVERY 8' IS CRAWL SPACE UNDER BUILDING. | |
| 03/15/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) GAS LINE REPAIR MADE WHETER SERVICE GOES BELOW GRADE AND PASSES UNDER BLDG. GUEST HOUSE DISCONNECTED AND CAPPED OFF. TEE REMOVED PIPE PROTECTED. 2) NO T & P RELIEF DRAIN OR WATER HEATER. 3) ALL APPLIANCES REQUIRE AGA OR CSA APPROVED GAS VALVES. 4) PLEASE PROVIDE LISTING FOR UNVENTED WALL HEATERS. 5) CALL IN ALL REQUIRED INSPECTIONS. 6) I DIDN'T SEE THE BOND BETWEEN GAS AND WATER PIPING | |
| 03/14/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 03/11/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* NOT READY | |
| 03/10/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) THIS INSPECTION IS FOR GAS LINE REPLACE. BLACK IRON PIPE MAY NOT BE INSTALLED IN OR ON THE GROUND UNDER ANY BLDG. OUTSIDE THE BLDG. BELOW GRADE PIPING TO BE SCOTCHCOAT. YOU HAVE DISCONNECTED THE PIPING BELOW GRADE, AND CAPPED IT OFF. PLUG OR REMOVE EXISTING, AND REPLACE CAPPED TEE WITH A COUPLING. ALL BELOW GRADE EXTERIOR PIPING AND FITTINGS TO BE PROTECTED 2) UNABLE TO COMPLETE INSPECTION BECAUSE NOBODY IS HOME 3) PLEASE CALL IN ALL REQUIRED INSPECTION |