Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) ALL CORRECTIONS HAVE BEEN MADE. | |
| 03/21/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL EXTEND FRUNACE FLU VENT AND TERMINATE 2'0" ABOVE COOLER WHEN VENT IS LOCATED WITHIN 10' OF COOLER. 2) CANNOT HAVE A FLEX CONNECTOR PASS THRU WATER HTR HOUSING. SHALL PROVIDE HARD PIPE INTO HOUSING THEN CONNECT VAVLE & FLEX CONNECTOR. 3) SHALL CONNECT GROUND BONDING WIRE TO NEW GAS SYSTEM. 4) RE TEST THE SYSTEM. |
|
| 03/18/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME. |