Permit: T05PL00458

Parcel: 138111630


Addresses:

6253 S DUNTON AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/23/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) ALL CORRECTIONS HAVE BEEN MADE.
03/21/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL EXTEND FRUNACE FLU VENT AND TERMINATE 2'0" ABOVE COOLER WHEN VENT IS LOCATED WITHIN 10' OF COOLER. 2) CANNOT HAVE A FLEX CONNECTOR PASS THRU WATER HTR HOUSING. SHALL PROVIDE HARD PIPE INTO HOUSING THEN CONNECT VAVLE & FLEX CONNECTOR. 3) SHALL CONNECT GROUND BONDING WIRE TO NEW GAS SYSTEM. 4) RE TEST THE SYSTEM.
03/18/2005 PLUMBING - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920* PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME.