Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) ALL CORRECTIONS HAVE BEEN MADE | |
| 03/16/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) VENT FROM WATER HEATER TO BE EXTENDED MINIMUM 2' ABOVE TOP OF ROOF LINE WITH DOUBLE WALL VENT PIPING. 2) PROVIDE BONDING OF BUILDING GAS PIPING | |
| 03/09/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL REMOVE THE UNION IN LINE AND REPLACE WITH A RIGHT & LEFT HAND NIPPLE. 2) GAS LINE SHALL BE LOCATED A MINIMUN OF 6" ABOVE GROUND. 3) SHALL SEAL ALL GAS LINE. LINE PENETRATIONS THRU WALLS. ( EXTERIORS) 4) SHALL STRAP DOWN GAS SUPPLY DROP TO WATER HEATER. 5) SHALL EXTEND T & P DRAIN FOR WATER HTR TO DAYLIGHT AND TERMINATE 6" ABOVE GROUND AND CAP OFF 1 1/2" DRAIN. |