Permit: T05PL00425

Parcel: 134100530


Addresses:

318 S ALANDALE AV

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/15/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* T & P RELIEF DRAIN LINE CANNOT RUN UPHILL TO THE ROOF. MUST GO TO DAYLIGHT. IF USING THE ALTERNATE METHOD, PROVIDE A PETITION OF APPEAL. PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR. EXTEND FLUE VENT 3' ABOVE EVAP COOLER. RECALL FOR INSPECTION.
04/03/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) NO ONE HOME