Permit: T05PL00421

Parcel: 126190760


Addresses:

4302 E EASTLAND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/09/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
03/08/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) VALVE AT FURNACE TO BE UP STREAM OF FLEX. 2) VALVE AT WATER HEATER TO BE AGA OR CSA APPROVED. 3) PROVIDE LOWE COMBUSTION AIR 100 SQ INCHES AT WATER HEATER CLOSET. 4) DIRT IN PLANTER AREA AT SERVICE VALVE TO BE 6" BELOW VALVE. 5) PRIME & TAPE PIPING TO 6" ABOVE GRADE AT METER. 6) PROVIDE VACUUM BREAKERS ON HOS BIBS AT H20 SERVICE PIPING