Permit: T05PL00395

Parcel: 11621144A


Addresses:

118 S MELROSE AV

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/14/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/11/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SEE NOTE # 4 AS REQUESTED
03/04/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL APPLY YELLOW TAPE PRIMER ON ALL UNDERGROUND GAS FITTINGS & WRENCH MARKS THEN APPLY THE 10 MIL TAPE 2) SHALL MAINTAIN MIN OF 12" OF COVER FOR UNDERGROUND GAS LINE. 3) SHALL SEAL ALL GAS LINE PENETRATIONS THRU WALLS. 4) I MUST HAVE ACCESS TO ALL GAS APPLIANCES INSIDE DWELLING