Permit: T05PL00391

Parcel: 130160070


Addresses:

4350 E SYLVANE ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/04/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :* 30 PSI AIR TEST NEW 1" SCOTCH COAT FROM METER UNDERGROUND OVERHEAD TO WATER HEATER & FURNACE AND TO STOVE OK
03/03/2005 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :* 1) GAS PIPING TO BE ROUTED TO PROVIDE WATER HEATER REPLACEMENT SPACE. 2) WATER HEATER TEMPERATURE & PRESSURE RELIEF PIPING TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE SIGNE? BY CITY PETITION OF APPEAL FOR ALTERANATE FORM OF TEMP & PRESSURE RELIEF ON SITE WITH INSTALLATION. 3) PROVIDE BONDING OF BUILDING GAS PIPING FROM METER TO BUILDING 30 PSI AIR TEST OK. 4) SEE NOTE #1 AND RETEST