Permit: T05PL00369

Parcel: 117031760

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/02/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
02/28/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* UNABLE TO COMPLETE INSPECTION AS ADDRESSED 232 W UNIVERSITY BL #2 DOES NOT NEED AN INSPECTION. WHEN I DO AN INSPECTION YOU MAY WANT TO REMEMBER: GAS TO BE MINIMUM 12" DEEP. MAY NOT PASS UNDER A PORCH OR BLDG. 45 DEGREE ANGLE OF REPOSE FOR PIPING PARALLELLING FOOTING. SEAL EXTERIOR WALL PENETRATION. REVIEW SECTION ON COMBUSTION RELIEF