Permit: T05PL00351

Parcel: 126190990


Addresses:

808 S CATALINA AV

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/07/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 10 PSI AIR TEST FROM METER NOW 1" SCOTCH ?? UNDERGROUND TO EXSISTING BUILDING SERVICE ENTRACE TO WATER HEATER, FURNACE & STOVE OK. 1) PROVIDE BONDING OF BUILDING GAS PIPING. 889-1888
03/03/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) AIR TEST 10 PSI MINIMUM ENTIRE GAS SYSTEM WITH NO PRESSURE DROP FOR MINIMUM 15 MINUTES VIEWED BY INSPECTOR. 2) ALL APPLIANCES TO HAVE AGA OR CSA APPROVED. GAS VALVES. 3) WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING TO BE BE APPROVED RIDGID MATERIAL GRAVITY DRAIN TO DAYLIGHT ( NO FLEX) 4) PROVIDE BONDING OF BUILDING GAS PIPING