Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 10 PSI AIR TEST FROM METER NOW 1" SCOTCH ?? UNDERGROUND TO EXSISTING BUILDING SERVICE ENTRACE TO WATER HEATER, FURNACE & STOVE OK. 1) PROVIDE BONDING OF BUILDING GAS PIPING. 889-1888 |
|
| 03/03/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) AIR TEST 10 PSI MINIMUM ENTIRE GAS SYSTEM WITH NO PRESSURE DROP FOR MINIMUM 15 MINUTES VIEWED BY INSPECTOR. 2) ALL APPLIANCES TO HAVE AGA OR CSA APPROVED. GAS VALVES. 3) WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING TO BE BE APPROVED RIDGID MATERIAL GRAVITY DRAIN TO DAYLIGHT ( NO FLEX) 4) PROVIDE BONDING OF BUILDING GAS PIPING |