Permit: T05PL00315

Parcel: 135031610

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/22/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) PETITION OF APPEAL FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF TO BE ON SITE AT TIME OF INSPECTION AND INSTALLATION TO BE PER THAT APPEAL. 2) VENT FROM WATER HEATER WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOP OF COOLER INTAKE WITH APROVED VENT MATERIAL AND APPROVED VENT CAP. 3) VENT FROM WATER HEATER & FURNANCE TO BE DOUBLE WALL AT PENETRATION THRU CEILING & ROOF