Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE BONDING OF BUILDING GAS PIPING 2) WATER HEATER TEMPERATURE & PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT, APPROVED RECEPTOR OR PROVIDE PETITION OF APPEAL FOR ALTERNATE FORM OF T & P RELIEF WITH CORRECT INSTALLATION. |
|
| 02/21/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE SECTION 517.6 UPC. 2) SHALL EXTEND FURNACE FLU VENT MIN 2' ABOVE COOLER. 3) NO ONE HOME! I MUST HAVE ACCESS TO ALL GAS APPLIANCES INSIDE DWELLING. NOTE: THERE COULD BE OTHER CODE VIOLATIONS INSIDE. |