Permit: T05PL00293

Parcel: 135083100


Addresses:

7443 E 29TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/22/2005 PLUMBING - FINAL Approved IVRS - Inspection :* CORRECTION MADE
02/16/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 12 PSI AIR TEST NOW 1" SCOTCH COAT UNDERGROUND TO EXISTING SERVICE ENTRY TO WATER HEATER & FURANCE ( APPROVED) ( ONLY) OK. 1) VENT FROM FURNACE IN FURNACE CLOSET TO BE 6" CLEARANCE FROM ALL COMBUSTIBLES, DOUBLE WALL REQUIRES 1" CLEARANCE FROM COMBUSTIBLES. 2) WATER HEATER TEMPERATURE & PRESSURE RELIEF PIPING TO BE RIDGID PIPING ( NO FLEX ) AND GRAVITY DRAIN TO DAYLIGHT. 3) 3 SCREWS) CONNECTION FROM SINGLE WALL TO DOUBLE WALL VENT PIPING FROM WATER HEATER. 4) VENT FROM FURNACE WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOPOF COOLER INTAKE WITH APPROVED VENT MATERIAL & CAP.