Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/22/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* CORRECTION MADE |
| 02/16/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 12 PSI AIR TEST NOW 1" SCOTCH COAT UNDERGROUND TO EXISTING SERVICE ENTRY TO WATER HEATER & FURANCE ( APPROVED) ( ONLY) OK. 1) VENT FROM FURNACE IN FURNACE CLOSET TO BE 6" CLEARANCE FROM ALL COMBUSTIBLES, DOUBLE WALL REQUIRES 1" CLEARANCE FROM COMBUSTIBLES. 2) WATER HEATER TEMPERATURE & PRESSURE RELIEF PIPING TO BE RIDGID PIPING ( NO FLEX ) AND GRAVITY DRAIN TO DAYLIGHT. 3) 3 SCREWS) CONNECTION FROM SINGLE WALL TO DOUBLE WALL VENT PIPING FROM WATER HEATER. 4) VENT FROM FURNACE WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOPOF COOLER INTAKE WITH APPROVED VENT MATERIAL & CAP. |