Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE CALL GAS GO 889-1888 CARD AT METER SET | |
| 02/16/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL EXTEND T & P DRAIN TO DAYLIGHT WITH NO THREADS @ END OF PIPE. 2) SHALL EXTEND GAS SUPPLY CLOSER TO METER OR PROVIDE UNDERGROUND GAS LINE TO TRAILER CONNECTION. 3) SHALL REPLACE OLD GAS SHUT OFF VALVES @ FURNACE & WATER HTR 4) RE TEST THE SYSTEM. |
|
| 02/15/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* NOT READY FOR INSPECTION |