Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/17/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 02/16/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 1) PROVIDE BONDING OF BUILDING GAS PIPING. 2) WATER HEATER TEMPERATURE & PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT WITH RIGID APPROVED PIPING. 3) SECURE GAS PIPING AT WATER HEATER. 4) REMOVE THREADS PROTECTOR AT WATER HEATER & RETEST. 5) SECURE GAS PIPING AT DROP FOR EXTERIOR FIREPLACE/ GRILL |
| 02/15/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* PLEASE HAVE SOMEONE PRESENT TO PROVIDE ACCESS TO ENTIRE GAS SYSTEM AT TIME OF REINSPECTION. COULD NOT DO PM INSPECTION TODAY SORRY 9:23AM |