Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 03/01/2005 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
|
| 02/22/2005 |
PLUMBING - GAS PRESSURE TEST |
|
Partial Approval |
IVRS - Inspection :* 15 PSI AIR TEST FROM METER TO WALL FURNACE, STOVE, AND WATER HEATER OK. 1) PROVIDE BONDING OF BUILDING GAS PIPING SYSTEM. 2) VENT FROM WATER HEATER TO BE FLASHED PROPERLY AT ROOF OF BUILDING AND WEATHER PROOF ENCLOSURE. 3) VENT FROM WALL HEATER TO BE DOULBLE WALL WHEN WITHIN 1" FROM COMBUSTABLE AT ROOF LINE AND BE SECURED PROPERLY. 4) PIPING AT STOVE & WATER HEATER TO BE SECURED PROPERLY. 5) AGA OR CSA APPROVED GAS VALVES & FLEXES TO BE ON SITE FOR ALL APPLIANCES. |