Permit: T05PL00250

Parcel: 12005003C


Addresses:

4538 S 14TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/07/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) ALL CORRECTIONS HAVE BEEN MADE. 3) OK TO BACKFILL TRENCH
03/04/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL APPLY YELLOW TAPE PRIMER THEN APPLY 10-MIL TAPE TO ALL FITTINGS AND WRENCH MARKS UNDERGROUND. 2) SHALL EXTEND FURNACE AND WATER HTR FLU VENT 3'-0" ABOVE COOLER WHEN FLU VENT IS LOCATED WITHIN 10' OF COOLER. 3) SHALL REMOVE FLEX LINE IN T * P DRAIN AND INSTALL 3/4 DRAIN LINE WITH PITCH. MAY HAVE TO OPEN WALL TO LOWER EXISTING DRAIN.4) SHALL PROVIDE ALL FLEX CONNECTORS AND SHUT OFF VALVE FOR FURNACE.