Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/11/2005 | PLUMBING - GAS PRESS TEST FNL | Approved | IVRS - Inspection :* 1) NO SUCH THING AS TT 2020-HAD TO WAIT FOR SOMEONE TO COME ALONG. 2) PRESSURE TEST OK. 3) OK TO BACKFILL. 4) NEED TO SEE FINAL CONNECTION TO APPLIANCE. | |
| 02/10/2005 | PLUMBING - GAS PRESS TEST FNL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/09/2005 | PLUMBING - GAS PRESS TEST FNL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/07/2005 | PLUMBING - GAS PRESS TEST FNL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 10 PSI MINIMUM TEST PRESSURE TO BE ON GAS PIPING SYSTEM INTO HEARTH OF FIRE PIT. FOR 15 MINUTES IWHT NO PRESSURE LOSS. 3) ALL FITTINGS & TOOL MAR??UNDERGROUND TO BE PRIMED & TAPED WITH PIPE PRIMER & 10 MIL TAPE. |