Permit: T05PL00162

Parcel: 132100740


Addresses:

3218 S PINAL VISTA

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/28/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL REMOVE THE THREAD PROTECTORS IN GAS LINE UNDERGROUND AND PROVIDE APPROVED COUPLINGS. 2) SHALL USE APPROVED TAPE PRIMER FOR FITTINGS UNDERGROUND. THIS PRIMER IS YELLOW IN COLOR. 3) SHALL REPLACE ALL GAS VALVES WITH AGA OR CSA SHUT OFF VALVES @ RANGE AND POSSIBLE FURNACE. 4) CANNOT HAVE A FLEX CONNECTOR. PENTRATE THRU A WALL OR APPLICANCE HOUSING @ FURNACE. 5) SHALL EXTEND WATER HTR T & P DRAIN TO DAYLIGHT OR APPLY FOR A APPEAL IN OUR OFFICE FOR ALTERNATE METHOD OF TERMINATION OF T & P DRAIN. THIS FOM MY BE OBTAINED AT OUR OFFICE. 6) RE TEST THE SYSTEM 10LBS MIN 7) SHALL PROVIDE # 6 GROUND WIRE TO GAS LINE FOR BONDING. 8) SHALL PROVIDE ( 2) 10 X10 LOUVER GRILLS ON WATER HTR RM DOOR 12" ABOVE CEILING & 12" ABOVE FLOOR.