Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/21/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* 14 PSI AIR TEST NOW SCOTCH COAT UNDERGROUND TO EXISTING SERVICE ENTRANCE ( 2) TO WATER HEATER & FURNACE OK ONLY CORRECTION MADE GAS CARD AT METER. 889-1888 |
| 01/18/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 1) EXTEND PIPING AT METER TO MINIMUN 6" ABOVE GRADE WITH SCOTCH COATED PIPE PRIME & TAPE ALL FITTINGS & TOOL MARKS.2) HAVE ALL FITTINGS EXPOSED AND ALL PIPING SHADED PROPERLY. 3) WHERE ?? ARE NECESSARY LEFT _ RIGHT NIPPLES & COUPLINGS SHALL BE USED. 4) PROVIDE BONDING OF BUILDING GAS PIPING. 5) VENT FROM FURNACE TO BE DBL WALL TO 2' ABOVE TOP OF COOLER W?? WITHIN 10' OF COOLER INTAKE. 6) RIGID PIPE THRU FURNACE APPLIANCE HOUSING. 7) PROVIDE GAS ISOMETRIC OF YOUR GAS SYSTEM CITY APPROVED SHOWING FUTURE GAS GRILL. |