Permit: T05PL00087

Parcel: 136203220

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/19/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 15 PSI AIR TEST FROM METER EXISTING 1 1/2 TO POOL HEATER. NEW 1" SCOTCH COAT UNDER GROUND, RISE UP ALONG WALL BACK UNDERGROUND UP AT BUILDING ACROSS ROOF TO WATER HEATER, FIREPLACE, ROOF TOP UNIT OK
01/14/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)PROVIDE BONDING OF BUILDING GAS PIPING #4 WIRE. 2)WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES & C0UPLINGS SHALL BE USED. 3)AGA OR CSA APPROVED GAS VALVES TO BE USES AT ALL LOCATIONS. 4)PROVIDE ROOF FLASHINGS AT PIPE PENETRATIONS THRU ROOF. 5)EXPOSE UNDERGROUND PIPING FOR VIEWING OF PIPE PRIME & TAPE AT JOINTS & TOOL MARKS 6)WATER HEATER TEMPERATURE & PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT.