Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/26/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*CORRECTIONS MADE |
| 01/21/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 15 PSI AIR TEST FROM METER UNDERGROUND NEW SCOTCH COAT TO BUILDING UP OVERHEAD TO WATER HEATER & FURNACE ( ONLY ) 1) WATER HEATER TEMPERATURE PRESSURE RELIEF DRAIN PIPING TO BE FULL SIZE RIDGID PIPE GRAVITY DRAIN TO DAYLIGHT TERMINATE 90 DEGREE DOWN. NO GAS CARD REQUIRED. OK FOR CONTRACTOR TO HOOK UP METER AND TURN ON GAS. REINSPECTION FOR FINAL REQUIRED PER NOTE #1 |