Permit: T05PL00072

Parcel: 128141170


Addresses:

642 S MAGNOLIA AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/19/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 10 PSI AIR TEST ON REPAIRED PIPING AT BUILDING FROM METER TO POOL HEATER, WATER HEATER, AND FURNACE ONLY OK CORRECTION MADE. GAS CARD LEFT AT METER. 889-1888
01/14/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES & COUPLINGS SHALL BE USED. 2)PRIME & 10 MIL TAPE ALL UNDERGROUND FITTINGS & TOOL MARKS. 3)PIPING AT POOL HEATER TO BE MINIMUM 6" ABOVE FINISH GRADE AND UNDERGROUND PIPING TO BE SCOTCH COATED PRIMED & TAPED WITH 3' MAXIMUM FLEX LENGTH 4)10 PSI AIR TEST MINIMUM AT TIME OF INSPECTION WITH NO PRESSURE DROP FOR 15 MINUTES.