Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05OT02736

Parcel: 130140260


Addresses:

4150 E 22ND ST


Inspection Status: Approved

Inspection History: SIGN ELECTRIC

Permit Number - T05OT02736

Inspection Description - SIGN ELECTRIC

Inspection Status - Approved

Date Description Inspector Results Comments
09/23/2009 SIGN ELECTRIC Approved IVRS - Inspection :*
10/29/2008 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*
CANCELED
03/16/2006 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*
1. PROVIDE ACCESS WALKWAY AS PER 600.21
2. SUPPORT M/C CABLE AS PER CODE
3. CORRECTLY LABEL SIGN CIRCUIT
4. SWITCH TO BE CAPABLE OF BEING LOCKED OUT 600.6
5. DO NOT ENERGIZE SIGN UNTIL FINALED BY ELECTRICAL INSPECTOR.
OK LETTERS