Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/08/2005 | PLUMBING - FINAL | Approved | ||
| 11/02/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 11/01/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE CORRECT RIDGID PIPING FOR WATER DISTRIBUTION 2) PROVIDE ONLY (1) SLIP JOINT CONNECTION DOWN STREAM OF TRAP 3) ALL FIXTURES REQUIRE SEPERATE HOT AND COLD SHUT OFF AT FIXTURE |
|
| 10/26/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*LAVATORY CONTINUOUS WASTE IS NOT TO CODE. THIS WASTE LINE CAN CANNOT TO THE SOUTH LAVATORY TRAIL PIECE WITH THE PROPER METHOD. WATER HTR T & P DRAIN SHALL RUN AND TERMINATE TO DAYLIGHT OR TO AN APPROVED RECEPTOR PUBLIC RESTROOM IS OK WATER HTR REQUIRES AN EXPANSION TANK. |