Permit: T05OT02601

Parcel: 11105026F

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/08/2005 PLUMBING - FINAL Approved
11/02/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
11/01/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE CORRECT RIDGID PIPING FOR WATER DISTRIBUTION
2) PROVIDE ONLY (1) SLIP JOINT CONNECTION DOWN STREAM OF TRAP
3) ALL FIXTURES REQUIRE SEPERATE HOT AND COLD SHUT OFF AT FIXTURE
10/26/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*LAVATORY CONTINUOUS WASTE IS NOT TO CODE. THIS WASTE LINE CAN CANNOT TO THE SOUTH LAVATORY TRAIL PIECE WITH THE PROPER METHOD.
WATER HTR T & P DRAIN SHALL RUN AND TERMINATE TO DAYLIGHT OR TO AN APPROVED RECEPTOR
PUBLIC RESTROOM IS OK
WATER HTR REQUIRES AN EXPANSION TANK.