Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05OT02556

Parcel: 13813001B


Addresses:

5701 S 12TH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05OT02556

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/02/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
03/08/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE WATER PIPING TO WC AND LAV USE
- APPROVED MATERIALS FOR EXTERIOR HORIZONTAL PIPING AND INTERIOR PIPING
- PROVIDE SHUT OFF VALVES AT FIXTURES
- PROVIDE HB VACUUM BREAKERS AT ALL HOSE BIBBS
- FEMALE PLASTIC THREADS NOT ALLOWED WITH METAL MALE THREADS
- PROVIDE STRAINER/COVER ON FLOOR DRAIN