Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/06/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :*APPROVED PER CORRCTION AND APPEAL TO BUILDING OFFICIAL | |
| 11/16/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANSI 117.1 ACCESSIBILITY GUIDE 2) SIDEWALK TO BE ACCESSIBLE (RAMP FROM SIDEWALK) 3) LEVER HANDLE, NO KNOWLEDGE HARDWARE REQUIRED AT ACCESSIBLE ENTRIES, BATHROOM, BEDROOM AND COMMON AREAS 3) THRESHOLD TO BE NO MORE THAN 1/2" HIGH WITH NO MORE THAN 1/4" VERTICAL RISE 4) HALLWAY FOR SIDE ACCESS TO ACCESSIBLE SPACE (BED AND BATH) MUST BE 42" WIDE MINIMUM 5) CLEAR FLOOR SPACE REQUIRED AT ACCESSIBLE LAVATORY 6) RIM OF LAV TO BE NO HIGHER THAN 34" 7) LEVER HANDLES REQUIRED AT LAV, ACCESSIBLE TOILET AND ACCESSIBLE BATH REQUIRED 8) REPAIR TPRV DISCHARGE LINE 9) REAR EXIT REQUIRED TO BE SIDE HINGED 10) BACKFLOW PREVENTERS REQUIRED ON HOSE BIBS |
|
| 11/14/2005 | BUILDING - FINAL | Cancelled | ||
| 11/14/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* |