Permit: T05OT01673

Parcel: 10605145B


Addresses:

3785 N ORACLE RD


Inspection Status: Approved

Inspection History: SIGN SHOP

Permit Number - T05OT01673

Inspection Description - SIGN SHOP

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2005 SIGN SHOP Approved IVRS - Inspection :*
08/17/2005 SIGN SHOP Not ready for Inspection IVRS - Inspection :*
1) GTO TO BE SEPERATED AT SUPPORTS-ONLY ONE PER SUPPORT
2) FINISH REMOVING MASKING TAPE-COMBUSTIBLES
08/12/2005 SIGN SHOP Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAINTAIN GTO CLEARANCES FROM GROUNDED SURFACES UL 20.2.5 AND TABLE 20.2
2) WE HAVE COMBUSTIBLE ? INSIDE OF SIGN
3) BOND RACE WAYS 600.4 AND U1 SECTION 18-18.1
4) A MARKING LABEL IS NEEDED 600.4 AND UL 40.1
5) ISOLATE LINE SIDE CONDUCTORS TO SWITCH
08/10/2005 SIGN SHOP Not ready for Inspection IVRS - Inspection :*
1) CANCELLED BY TERRY