Inspection Status: Approved
Inspection History: SIGN ELECTRIC
Permit Number - T05OT01662
Inspection Description - SIGN ELECTRIC
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2006 | SIGN ELECTRIC | Approved | IVRS - Inspection :* OK SIGN |
|
| 02/27/2006 | SIGN ELECTRIC | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. SUPPORT M/C CABLE WITHIN 12" OF BOXES 2. M/C CABLE TO TERMINATE AS PER MANUFACTURED LISTING NOT PLASTIC BOX 3. SIGN CIRCUIT TO BE AS PER 600.5 4. USE APPROVED SEAL TITE FITTING |