Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05OT01456

Parcel: 13312006M

Inspection Status: Approved

Inspection History: SIGN ELECTRIC

Permit Number - T05OT01456

Inspection Description - SIGN ELECTRIC

Inspection Status - Approved

Date Description Inspector Results Comments
07/15/2005 SIGN ELECTRIC Approved IVRS - Inspection :*
06/29/2005 SIGN ELECTRIC Partial Approval IVRS - Inspection :* FINISH ITEMS 1,3,5 OF PREVIOUS INSPECTION
06/28/2005 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :* 1) SUPPORT GTO CABLES IN RACE WAYS. 2) INSTALL MAKING LABELS 600.4 3) FINISH POWER INSTALLATION. 4) NEON TUBING BOTTOM SIGN NOT INSTALLED AT THIS TIME. 5) BOND RACEWAY.
06/24/2005 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*